26 June 2008 · Delegated - Senior Planning Officer (Mrs F Mullen)
Ballavale New Farmhouse, Ballavale Road, Santon, Isle Of Man, IM4 1eh
The application sought approval for minor amendments to extensions previously permitted under PA 07/01422/B at Ballavale Farmhouse, a detached former agricultural dwelling with sizeable gardens on Ballavale Road, Santon.
Click a button above to find applications similar to this one.
See how this application compares to similar ones — policies, conditions, and outcomes side by side.
The proposed changes do not increase the amount of accommodation which has been permitted and do not have any adverse impact on the appearance of the property.
Time limit
The development hereby permitted shall commence before the expiration of four years from the date of this notice.
Approved drawings
This permission relates to the alterations and extensions shown in drawings 1125-00, -01A, -02A, -03A, -04D, -05D and -06C all received on 9th May, 2008.
Do not oppose
Do not oppose
Note received - recommends smoke detection (Building Regulations matter)
NOTE 1: Underground Cables/Overhead Lines present; contact for safety before works
Manx Electricity Authority notes underground cables/overhead lines nearby and requests contact prior to works; Department of Transport does not oppose; Fire and Rescue Service recommends smoke detection installation.
Key concern: Underground Cables/Overhead Lines present in the area
Manx Electricity Authority
Conditional No ObjectionThere are Underground Cables/Overhead Lines present in the area indicated in you Planning Application; NOTE 1; The Authority wish to express their interest in the following planning applications, and request that a condition of planning be that the applicant must contact the Authority
Conditions requested: The applicant must contact the Authority; Contact our Network Operations Department, Manx Electricity Authority, (Tel. 687687) to discuss working practices around Cables and Overhead Lines which may be required to be diverted before any work can be carried out on site; Contact the M.E.A. for Electrical Site Safety 5 documents, (Tel. 687766), before any work is carried out on site; All work to be carried out with reference to Health and Safety Executive Guidance Notes HS(G)47 & GS6; MEA requires 24 hours unrestricted access to the cables in the Public Highway
Department of Transport
No ObjectionDo not oppose
Fire and Rescue Service
Conditional No ObjectionThe installation of mains wired, interconnected domestic smoke detection conforming to BS 5466 : Part 1 : 2000, and installed to conform with BS 5839 : Part 6 : 1995, is recommended
Conditions requested: The installation of mains wired, interconnected domestic smoke detection conforming to BS 5466 : Part 1 : 2000, and installed to conform with BS 5839 : Part 6 : 1995, is recommended in accordance with Section 1 of the Building Regulations 2000 - Approved Document B